Ship Clinical Application Changes Faster Without Increasing Patient-Care Availability Risk
Despite passing all testing and deploying successfully, healthcare software can still cause issues for users. An update to a prescribing application passes all tests and deploys. However, alterations to a mapping mean that prescriptions are no longer being passed to the pharmacy system. Underpinning infrastructure, API development, and dashboards are all functioning well. Yet, the clinical process has been disrupted.
Healthcare release risk stems from the difference between the technology working and processes functioning. Rather than being mutually exclusive, good healthcare releasers tend to be those that have performed the greatest due diligence in preparation for release; they are not usually those that conduct the least testing.
Understanding this issue is even more crucial now. According to ONC, greater than 99% of non-federal acute care hospitals had implemented a certified EHR by 2024.
Further, in 2023, 70% of such hospitals at least occasionally sent, received, searched, and combined external non-health-related information, compared to 46% in 2018. Each of these interconnects presents a potential point of failure for future releases. Below are areas for engineers to focus on to achieve rapid and secure release of clinical software changes.
1. Measure Clinical Availability, Not Just Uptime
Whilst infrastructure assessment identifies whether or not software is operating, clinicians require insight into whether or not they can perform a function.
Assess the availability of key clinical processes.
Trace through processes including submission, validation, storage, processing and confirmation. Identify key processes that must function and then establish a quantifiable assessment for each:
- Registration and patient matching.
- Clinical activity and patient record keeping.
- Prescribing and pharmacy interfacing.
- Laboratory ordering and result provision.
- Billing and claims processes (where relevant).
Synthetic processes, interface, application and database assessments identify further points of failure than infrastructure assessments. Only when all key clinical processes can be completed can a release be deemed to be well-functioning.
2. Map Dependencies Before You Change Anything
Although clinical software is often not standalone, limited alterations can influence numerous other services, including authentication, mappings, interfacing, reporting, external laboratories, pharmacies, and third-party software.
Pre-release, analyse the upstream and downstream dependencies for a particular feature, comprising APIs, HL7 and/or FHIR, databases, authentication and batch processes. Altering, for example, a patient identification attribute can influence ADT messages, patient matching, document access and billing interfacing. Even if the application can store updated data, other systems may either reject or incorrectly process it.
Version control, contract and dependency analyses transform dependency analysis into a structured process. They also demonstrate which services should and can be released together and which can be released separately. This is the initial true driver of rapidity.
3. Match the Deployment Method to the Change
No single strategy is safe for every application. The right choice depends on architecture, transaction volume, and whether old and new versions can run side by side.
| Strategy | Best for | Main risk | Recovery behavior |
| Rolling deployment | Stateless services where old and new versions share the same database and contracts | Mixed versions during rollout can behave inconsistently | Roll forward or halt the rollout; in-flight transactions still need review |
| Blue-green deployment | Changes that benefit from full pre-switch validation | Database changes and external transactions are not covered by the traffic switch | Fast application rollback by switching traffic back; data must be reconciled separately |
| Canary release | High-volume services where traffic can be segmented | Inconsistent experiences if the same user or patient hits both versions | Pull the canary; limited exposure keeps the impact small |
| Feature flag | Turning functionality on or off without redeploying | Does not reverse migrations or transactions already processed | Disable the flag; confirm data written under the new behavior is still valid |
The question is not which strategy sounds fastest. It is whether the method supports safe version transitions, controlled exposure, and a tested recovery path. Never assume a pattern delivers zero downtime just because it is named that way.
.4. Keep Database Changes and Integrations Backward Compatible
Updating or deleting a database attribute can cause issues for legacy systems still in use. The expand-migrate-contract method prevents this:
Expand: Introduce the new database attribute but retain the legacy attribute too.
- Dual enable: Create code to handle both attributes.
- Migrate: Update legacy data and check that it is correctly transformed.
- Transfer: Transition application reading and writing to utilise the new attribute.
- Contract: Only delete the legacy attribute when no further services depend on it.
As noted above, apply the same principles to interfaces. For HL7v2, assess segments, attributes, acknowledgements and error-handling. For FHIR, evaluate profiles, mandatory attributes, referencing and authorisation scopes together with version compatibility.
An acknowledgement does not confirm that a downstream clinical process has been executed. Assess processes from end-to-end – including acceptance, processing, retrying and error handling, alongside any necessary data reconciliation. Implement idempotent controls so that retrying does not lead to double prescribing or double results, for example.
5. Test What Clinicians Actually Do
Unit and API testing assesses individual software aspects. However, it does not always illustrate how software will function within integration environments and in actual clinical situations.
Structure testing around typical clinical processes and assess these via the user interface, APIs, databases, and interfaces. Test using both correct and erroneous data. Assess software handling of slow responses and duplicate messages. In addition, simulate downstream system unavailability.
A laboratory interfacing test should encompass functions such as ordering, interfacing, acknowledgement, result provision, patient matching, and display of results from the clinician’s perspective.
Test role-based access, auditing, data, and high-transaction performance. Involve clinical process representatives in user acceptance testing to enable evaluation of the release in the context of actual clinical processes.
Automate wherever possible. Manual testing should, though, be reserved for areas where clinical relevance is important. Again, this distinction is key to enabling continual release capability.
6. Monitor the Release and Plan the Recovery
In addition to releasing, it is important to monitor a release. Develop tailored dashboards to show application error rates, API response times, database performance, interface message queues, message rejection statistics, retry levels, and the availability of key clinical processes. Contrast these with pre-release data and determine alert levels relative to usual application behaviour.
A rollback procedure must include details of who can authorise rollback, which version of software should be reinstated, how database backward compatibility can be achieved, and how transactions undertaken during the release can be reconciled. Simply rolling back code may not be sufficient to undo database and message modifications.
Preparing for rollback also has a regulatory dimension. According to the HIPAA Security Rule (45 CFR 164.308(a)(7)), healthcare organisations must have a contingency plan comprising data backup, disaster recovery and emergency operating procedures for electronic protected health information. Specifications for these must include processes for testing, updating and conducting a criticality analysis. Your rollback and downtime procedures should align with these requirements and be practised.
7. Build Governance That Speeds Releases Up
As outlined above, processes can be made less risky. This section explores how to convert this into greater release rapidity.
- Release discrete changes. Smaller changes are simpler to test and understand and also easier to roll back. Larger-scale and less frequent releases focus risk.
- Group changes according to risk. Pre-approving low-risk changes (for example, visual-only alterations with no impact upon prescribing, results, or interfacing) enables rapid release. Higher risk changes (for example, prescribing, clinical decision support, and mapping) require comprehensive evaluation, including clinical safety sign-off.
- Consider clinical transaction levels. Release software during periods of low clinical transactional activity and avoid busy patient times.
- Automate recording. Automatically logging regression, contract, and release data expedites review of change impact.
- Understand regulatory requirements. Modifications to certified EHRs might be subject to regulations set out in the ONC Health IT Certification Program. Moreover, some clinical decision support and analogous software may be regulated as medical devices by the FDA. Speak to your compliance department to understand regulatory requirements prior to, not following, a release.
Make Every Clinical Application Release More Reliable
CapMinds’ healthcare technology specialists support you to optimise release processes, enhance HL7/FHIR interoperability, refine clinical processes and boost application reliability. This therefore enables your teams to release changes promptly, without impacting the continuity of patient care.